1254wi03_ENGLISH
Questa pubblicazione interattiva è stata creata con FlippingBook, un servizio di streaming di file PDF online. Non serve scaricare o aspettare. Apri e comincia a leggere direttamente!
CERTIFICATE Certified Passive House Component
Passive House Institute Dr. Wolfgang Feist 64283 Darmstadt Germany
Component-ID 1254wi03 valid until 31st December 2020
Category:
Window Frame
Manufacturer: METRA spa, Rodengo Saiano, Italy Product name: NC90STH HES WS
This certificate was awarded based on the following criteria for the cool, temperate climate zone
Comfort U W = 0.79 ≤ 0.80W/(m 2 K) U W , installed ≤ 0.85W/(m 2 K) with U g = 0.70W/(m 2 K)
Hygiene f Rsi =0.25
≥ 0.70
cool, temperate climate
ph C
CERTIFIED COMPONENT Passive House Institute
Passive House efficiency class
ph E
ph D
ph B
ph A
ph C
www.passivehouse.com
METRA spa Via Stacca 1, 25050 Rodengo Saiano, Italy T +39 0306819982 | B a.mafezzoni@metra.it | Í http://www.metra.it |
20 o C 18 o C 16 o C 14 o C 12 o C 10 o C
8 o C 6 o C 4 o C 2 o C 0 o C
-2 o C -4 o C -6 o C -8 o C -10 o C
Calculation model
Isothermal
Description
Aluminium frame with thermal separation (low lambda PA 0.021 W/(mK)) and insulation (PA foam 0.036 W/(mK)); Pane thickness: 48 mm (4/18/4/18/4), rebate depth: 16 mm, spacer: SWISSPACER Ultimate
Explanation
The window U-values were calculated for the test window size of 1.23m × 1.48m with U g = 0.70W/(m 2 K). If a higher quality glazing is used, the window U-values will improve as follows:
Glazing U g = 0.70 0.60 0.58 0.52 W/(m 2 K) ↓ ↓ ↓ ↓ Window U W = 0.79 0.74 0.73 0.70 W/(m 2 K)
Transparent building components are classified into efficiency classes depending on the heat losses through the opaque part. The frame U-Values, frame widths, thermal bridges at the glazing edge, and the glazing edge lengths are included in these heat losses. A more detailed report of the calculations performed in the context of certification is available from the manufacturer. The Passive House Institute has defined international component criteria for seven climate zones. In principle, components which have been certified for climate zones with higher requirements may also be used in climates with less stringent requirements. In a particular climate zone it may make sense to use a component of a higher thermal quality which has been certified for a climate zone with more stringent requirements.
Further information relating to certification can be found on www.passivehouse.com and passipedia.org.
2/4
NC90STH HES WS
www.passivehouse.com
U -value frame
Frame width
Ψ -panel edge
Temp. Factor
Frame values
b f
U f
f Rsi =0.25
Ψ g
W/(m 2 K)
mm
W/(mK)
[-]
Top
180
0.78
0.026
0.77
(to)
Side
180
0.78
0.026
0.77
(s)
Bottom
180
0.78
0.026
0.77
(bo)
Mullion 2 casements
194
0.91
0.025
0.77
(m2)
Spacer: SWISSPACER Ultimate
Secondary seal: Polysulfid
Validated installations
EIFS U Wall = 0.13W/(m
Insulated formwork blocks U Wall = 0.15W/(m 2 K)
Timber frame U Wall = 0.13W/(m
2 K)
2 K)
W/(mK)
W/(mK)
W/(mK)
Ψ install
Ψ install
Ψ install
Top
0.013 0.013 0.022
Top
0.014 0.014 0.023
Top
0.018 0.018 0.027
Side
Side
Side
Bottom
Bottom
Bottom
2 K)
2 K)
2 K)
U W , installed = 0.84W/(m
U W , installed = 0.84W/(m
U W , installed = 0.85W/(m
Component-ID: 1254wi03
3/4
www.passivehouse.com
www.passivehouse.com
Made with FlippingBook - Online Brochure Maker