1254wi03_ENGLISH

Questa pubblicazione interattiva è stata creata con FlippingBook, un servizio di streaming di file PDF online. Non serve scaricare o aspettare. Apri e comincia a leggere direttamente!

CERTIFICATE Certified Passive House Component

Passive House Institute Dr. Wolfgang Feist 64283 Darmstadt Germany

Component-ID 1254wi03 valid until 31st December 2020

Category:

Window Frame

Manufacturer: METRA spa, Rodengo Saiano, Italy Product name: NC90STH HES WS

This certificate was awarded based on the following criteria for the cool, temperate climate zone

Comfort U W = 0.79 ≤ 0.80W/(m 2 K) U W , installed ≤ 0.85W/(m 2 K) with U g = 0.70W/(m 2 K)

Hygiene f Rsi =0.25

≥ 0.70

cool, temperate climate

ph C

CERTIFIED COMPONENT Passive House Institute

Passive House efficiency class

ph E

ph D

ph B

ph A

ph C

www.passivehouse.com

METRA spa Via Stacca 1, 25050 Rodengo Saiano, Italy T +39 0306819982 | B a.mafezzoni@metra.it | Í http://www.metra.it |

20 o C 18 o C 16 o C 14 o C 12 o C 10 o C

8 o C 6 o C 4 o C 2 o C 0 o C

-2 o C -4 o C -6 o C -8 o C -10 o C

Calculation model

Isothermal

Description

Aluminium frame with thermal separation (low lambda PA 0.021 W/(mK)) and insulation (PA foam 0.036 W/(mK)); Pane thickness: 48 mm (4/18/4/18/4), rebate depth: 16 mm, spacer: SWISSPACER Ultimate

Explanation

The window U-values were calculated for the test window size of 1.23m × 1.48m with U g = 0.70W/(m 2 K). If a higher quality glazing is used, the window U-values will improve as follows:

Glazing U g = 0.70 0.60 0.58 0.52 W/(m 2 K) ↓ ↓ ↓ ↓ Window U W = 0.79 0.74 0.73 0.70 W/(m 2 K)

Transparent building components are classified into efficiency classes depending on the heat losses through the opaque part. The frame U-Values, frame widths, thermal bridges at the glazing edge, and the glazing edge lengths are included in these heat losses. A more detailed report of the calculations performed in the context of certification is available from the manufacturer. The Passive House Institute has defined international component criteria for seven climate zones. In principle, components which have been certified for climate zones with higher requirements may also be used in climates with less stringent requirements. In a particular climate zone it may make sense to use a component of a higher thermal quality which has been certified for a climate zone with more stringent requirements.

Further information relating to certification can be found on www.passivehouse.com and passipedia.org.

2/4

NC90STH HES WS

www.passivehouse.com

U -value frame

Frame width

Ψ -panel edge

Temp. Factor

Frame values

b f

U f

f Rsi =0.25

Ψ g

W/(m 2 K)

mm

W/(mK)

[-]

Top

180

0.78

0.026

0.77

(to)

Side

180

0.78

0.026

0.77

(s)

Bottom

180

0.78

0.026

0.77

(bo)

Mullion 2 casements

194

0.91

0.025

0.77

(m2)

Spacer: SWISSPACER Ultimate

Secondary seal: Polysulfid

Validated installations

EIFS U Wall = 0.13W/(m

Insulated formwork blocks U Wall = 0.15W/(m 2 K)

Timber frame U Wall = 0.13W/(m

2 K)

2 K)

W/(mK)

W/(mK)

W/(mK)

Ψ install

Ψ install

Ψ install

Top

0.013 0.013 0.022

Top

0.014 0.014 0.023

Top

0.018 0.018 0.027

Side

Side

Side

Bottom

Bottom

Bottom

2 K)

2 K)

2 K)

U W , installed = 0.84W/(m

U W , installed = 0.84W/(m

U W , installed = 0.85W/(m

Component-ID: 1254wi03

3/4

www.passivehouse.com

www.passivehouse.com

Made with FlippingBook - Online Brochure Maker